Bürkert GmbH & Co. KG

Type 8741 - Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases

Type 8741 - Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases

Bürkert GmbH & Co. KG

Description

The mass flow controller (MFC) / meter (MFM) Type 8741 for gases is suitable for a wide range of applications and available with Industrial Ethernet, analogue or fieldbus interfaces. The version with CANopen based Bürkert system bus (büS) is suitable for the integration into existing CANopen networks, as well as Industrial Ethernet or fieldbus networks in combination with the fieldbus gateway of Type ME43. The second option is tailor-made for applications with many control loops. Up to 32 MFC / MFM can be connected to one fieldbus gateway. Type ME43 translates the internal CANopen based communication to industry standards for both Industrial Ethernet and fieldbuses. The mass flow controller / meter can always be switched between büS and CANopen communication. Type 8741 can be configured as MFM or MFC. Optional, up to four different gases calibrations can be stored in the device. The thermal MEMS sensor is located directly in the gas stream and therefore reaches very fast response times. A direct-acting proportional valve as regulating unit guarantees high sensitivity. The integrated PI controller ensures outstanding control characteristics of the MFC / MFM.

  • Nominal flow ranges from 0.010 l/min to 160 l/min
  • High accuracy and repeatability
  • Very fast response times
  • Easy device exchange through configuration memory
  • Optional: USP Class VI, FDA, EG 1935 conformity

More products by Bürkert GmbH & Co. KG

Type 8098 - FLOWave SAW flowmeter

The Type 8098 flowmeter is part of the FLOWave product range. It is based on SAW (Surface Acoustic Waves) technology and is mainly designed for applications with the highest hygienic demands. This is achieved by using: suitable stainless steel materials, a measuring tube free of any wetted parts except for the actual tube, the ideal outer hygienic design. FLOWave offers a range of integrated functions, including the advantages of flexibility, ease of cleaning, compact dimensions, lightweight, easy installation and handling, and is compliant with numerous standards. Optimal measurement results can be achieved with homogeneous liquids, free of air and solid particles. For liquids with high viscosity, an integrated viscosity compensation can be activated. Gas and steam cannot be measured; however, their flow does not have any negative effect on the device or its operation and other liquids flowing through afterwards are measured correctly as before. Beside volume flow, a density measurement optional feature is available. With this option, the mass flow is calculated based on volume flow and density measurements. Special functions derived from further process values (differentiation factor (DF), acoustic transmission factor, concentration) offer additional information about the particular liquid in use (for details, see data sheet).

  • No obstacles inside the measuring tube, compact, lightweight and low energy consumption
  • Conforms to hygienic requirements, CIP/SIP compatible
  • Ideal for liquids with low or no conductivity
  • Digital communication, parameterisation via Communicator, display
  • Optional: ATEX/IECEx certification, II 3G/D

Type ME63 - Industrial Ethernet gateway, IP65/ IP67/ IP69k

The Industrial Ethernet gateway Type ME63 is the central control unit for Bürkert products (valves, sensors, process control systems), which is based on EDIP (Efficient Device Integration Platform) and used in processes requiring a high degree of protection. Type ME63 consists of a fieldbus gateway which transmits the internal CANopen-based communication of the Bürkert field devices to all common industry standards for Industrial Ethernet. With the help of eight M12 ports, CANopen-based Bürkert field devices can be connected directly to the gateway Type ME63. The power supply of the field devices can be provided either by an M12 L-Power (up to 32A) or an A-coded M12 connector (up to 4A). One of these additional participants can be either Type ME64 (I/O module) or a passive junction box (included as an accessory part with this data sheet). The passive junction box is intended to simply integrate further participants into the proprietary bus system of the gateway Type ME63. The power supply via the M12 L-Power input can supply further field devices located close to the process via the second M12 L-Power output. Also integrated is an Ethernet switch which allows the direct integration of further field devices located close to the process in the Ethernet communication.

  • Gateway for Industrial Ethernet standards, incl. OPC UA, for use in environments requiring a high degree of protection
  • Up to 128 input and 128 output variables can be transmitted
  • Simpler integration of Bürkert devices in the process control level through individually configurable device description files
  • Connection of up to eight end devices or junction box modules, connection of up to 126 CANopen participants
  • Integrated central configuration management for easy device replacement